Introduction
|
|
The UV 1600/1800
series are developed for precise testing with a stray of light of only
0.05%T. The value is evident from the performance provided everyday. The
local stand-alone software provides functions of Basic Mode, Quantitative
Test and Kinetics and System Utilities.
|
|
Fundamental Principle
|
|
Data Store Function
The Ram has the
capability of saving 200 separate groups of data which can be recalled at any
time and most importantly, if a sudden loss of power occurs. Users don't need
to write down each test result in the notebook, thus saving time and
increasing work efficiency.
Standard Curve Build
and Store
Users can build their
own standard curve on the screen and save it within the RAM. The curves can
be reloaded at any time. Up to 100 curves can be stored.
Coefficient Method
If you know the
coefficients of the curve equation, you can input the values and use them to
test the samples directly.
Kinetics Test
The Kinetics curve can
be displayed in the screen, you can use this function to test the samples and
verify the instruments stability.
System Function
The instruments have
the ability to calibrate the wavelength accuracy and dark current
automatically by choosing the corresponding command in the Utility menu.
Super PC Software
(Optional)
The software functions
include 1) Kinetics 2) Quantitative Test 3) Wavelength Scan 4) Multi
wavelength Test 5) DNA/Protein Test
|
|
Features
|
|
The Milas Deuterium is
a world-leading lamp that has a long-lasting service life, high stability and
high brightness.
The Tungsten lamp also
ensures a long service life and high stability on the UV spectrophotometer.
The lamps feature
pre-aligned design, so there is no need for professional adjustment while
replacing a new one. Therefore users no longer need to hire professionals to
change or adjust lamps which greatly improves reliability and cuts down on
the maintenance expenses.
The D2 lamp and the W
lamp can be controlled individually to extend the lifetime. You can switch
off the D2 lamp when in visible range or switch off the W lamp when in
Ultraviolet range.
Excellent optical
performance
Low Stray Light
The Stray Light is
only 0.05%T which enables the user to decrease the analysis Relative Error
greatly.
High Wavelength
Accuracy
Adopt advanced Guide
Screw structure, which ensures the wavelength accuracy and repeatability.
Outstanding UV and
visible region are used with corresponding photometry accuracy of top-grade
instruments (NBS930D standard, standard solution), which enables the
instrument to be suitable for various quality control.
For more information
https://angstromadvancedinc.wordpress.com/
http://angstrom-advanced1.blogspot.com/
http://angstrom-advanced.blogspot.com/
https://www.facebook.com/Angstrom-Advanced-121251874597862/
http://angstromadvancedinc1.blogspot.com
https://twitter.com/AngstromAdvance
|
Tuesday, November 29, 2016
Angstrom Advanced UV1600/1800 series spectrophotometer
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment