Friday, December 2, 2016

Angstrom Advanced combined Thermogravimetric Analysis (TGA) , Differential Thermal Analysis(DTA) and Differential Scanning Calorimetry(DSC) Systems

TGA/DSC/DTA Apparatus
 
Temperature range: according to selected furnace
 
-150 … 2000°C, for cp determination up to 1500°C
 
Consisting of:
A) Basic Unit
Basic system with sample carrier support with reproducible adjustment, purge gas inlet to the sample, inbuilt µV-preamplifier electronics and electric motor driven furnace hoist (basic system). The system is suitable for measurements under normal atmosphere, in dynamic and static inert gas atmosphere, it is evacuable (down to 10E-2 mbar).
 
Accessory kit for furnace hoist for one furnace, with manual pivoting mechanism
           
Silicon Carbide furnace, working temperature range 25 ... 1550°C high temperature tube furnace with SiC heating element, integrated, exchangeable protective tube for gas flow with stop valve, air-cooled double shell, integrated control thermocouple type S, voltage supply 75 V max. (for measurements in the low temperature range helium has to be used as sample atmosphere)
 
B) Sample Carrier
Sample carrier system, also for cp determinations, complete with radiation shield and thermocouples type S
 
2 sample crucibles 399.205 (PtRh) with lids 399.860 for temperature range 25 ... 1500°C, for cp-determinations ... 1400°C
 
2 sample pans 399.972 (Al2O3) with lids 399.973 for temperature range 25 ... 1650°C
 
C) Software Package
Software with data acquisition, storage and evaluation under MS WINDOWS, 32 bit.
 
Features:
Multitasking with simultaneous operation of several TA systems and simultaneous evaluation
Graphical user surface, integrated detailed HELP system       
                                                                             
D) Calibration
DSC/DTA calibration kit (temperature and enthalpy)
 
Temperature range -50 ... 750°C, consisting of 8 samples (400 mg each) with manufacturer certificate and detailed calibration instructions, for use in Al2O3 crucible
 
E) Vacuum pump for measurements under pure atmosphere
Evacuating system for manual operation, with double-head diaphragm vacuum pump (final pressure 10E-5 mbar), with valves and connection lead (115/230 V, 50/60 Hz)



 
 
 


Tuesday, November 29, 2016

Angstrom Advanced UV1600/1800 series spectrophotometer



Introduction
The UV 1600/1800 series are developed for precise testing with a stray of light of only 0.05%T. The value is evident from the performance provided everyday. The local stand-alone software provides functions of Basic Mode, Quantitative Test and Kinetics and System Utilities.
Fundamental Principle
Data Store Function
The Ram has the capability of saving 200 separate groups of data which can be recalled at any time and most importantly, if a sudden loss of power occurs. Users don't need to write down each test result in the notebook, thus saving time and increasing work efficiency.
Standard Curve Build and Store
Users can build their own standard curve on the screen and save it within the RAM. The curves can be reloaded at any time. Up to 100 curves can be stored.
Coefficient Method
If you know the coefficients of the curve equation, you can input the values and use them to test the samples directly.
Kinetics Test
The Kinetics curve can be displayed in the screen, you can use this function to test the samples and verify the instruments stability.
System Function
The instruments have the ability to calibrate the wavelength accuracy and dark current automatically by choosing the corresponding command in the Utility menu.
Super PC Software (Optional)
The software functions include 1) Kinetics 2) Quantitative Test 3) Wavelength Scan 4) Multi wavelength Test 5) DNA/Protein Test 
Features
The Milas Deuterium is a world-leading lamp that has a long-lasting service life, high stability and high brightness.
The Tungsten lamp also ensures a long service life and high stability on the UV spectrophotometer.
The lamps feature pre-aligned design, so there is no need for professional adjustment while replacing a new one. Therefore users no longer need to hire professionals to change or adjust lamps which greatly improves reliability and cuts down on the maintenance expenses.
The D2 lamp and the W lamp can be controlled individually to extend the lifetime. You can switch off the D2 lamp when in visible range or switch off the W lamp when in Ultraviolet range.
Excellent optical performance
Low Stray Light
The Stray Light is only 0.05%T which enables the user to decrease the analysis Relative Error greatly.
High Wavelength Accuracy
Adopt advanced Guide Screw structure, which ensures the wavelength accuracy and repeatability.
Outstanding UV and visible region are used with corresponding photometry accuracy of top-grade instruments (NBS930D standard, standard solution), which enables the instrument to be suitable for various quality control.
For more information
https://angstromadvancedinc.wordpress.com/
http://angstrom-advanced1.blogspot.com/
http://angstrom-advanced.blogspot.com/
https://www.facebook.com/Angstrom-Advanced-121251874597862/
http://angstromadvancedinc1.blogspot.com
https://twitter.com/AngstromAdvance

Angstrom Advanced Model Gold 54 UV/VIS Scanning Spectrophotometer


Model Gold 54 UV/VIS Scanning Spectrophotometer

Features
  • Display Mode: 4 digit LED
  • Lamp:
    • Hamamatsu L2D2 long life (over 3000 hours)
    • Deuterium Lamp and RoYal long life (over 10000 hours)
    • Halogen-Tungsten Lamp with patent technical combination
  • Interface: RS232 Serial
  • Measurement: 15 × 12 × 9 Inches
  • Weight: 22lb
  • Curny-terner configuration diffraction grating monochromator, non-spherical light source optical path & precise grid, whole aluminum metal alloy die-castings, patent structure of mirror rack, excellent UV S/N
  • Patented Deuterium / Halogen-Tungsten lamp and spectral energy correction system
  • With Qualitative-quantitative data processing software package, save/print/output applied to spectrum scanning or timing scanning, etc
  • Adopting computerized measuring system, accurate T-A transformation, auto 0% & 100% adjustment, direct concentration readout, concentration factor setting, GOTO
  • Spacious sample compartment, 4 position cuvette rack, suitable for 1-5 cm optical path rectangular cells
Specifications
Wavelength Range
200~1000nm
Wavelength Accuracy
±2nm
Wavelength Repeatability
£0.5nm
Photometric Range
0.0~199.9%T
-0.3~2.999A
1~9999F
0~999C
Spectral Slit Width
2nm
Transmittance Accuracy
±0.5%T(NBS930D)
Stray Light
< 0.3%T(220nmNal)
For more information
https://angstromadvancedinc.wordpress.com/
http://angstrom-advanced1.blogspot.com/
http://angstrom-advanced.blogspot.com/
https://www.facebook.com/Angstrom-Advanced-121251874597862/
http://angstromadvancedinc1.blogspot.com
https://twitter.com/AngstromAdvance

Monday, November 28, 2016

Angstrom Advanced Model 752S UV/VIS Spectrophotometer


Model 752S UV/VIS Spectrophotometer
Manual monochromator with dual lamps for UV and Visible wavelength
Introduction
The model 752S is a simple single beam spectrophotometer extending into the UV region. The wavelength is set manually from the dial on the front panel. Direct readout of Transmission or Absorption on LED display. The 752S incorporated a high-brightness Hamamatsu deuterium lamp for UV and a tungsten lamp for the visible wavelengths.
Measured values can be transferred to a PC via the RS232 link for further analysis. Low price and simple design make this instrument ideal for education or routine analysis. 
Applications
  • Analysis of unsaturated & asymmetrical electron compounds and compounds possessing conjugate systems.
  • Analysis of organic compounds, biological products and RNA.
  • Analysis of complex inorganic ionic compounds and nonferrous & ferrous metals.
Specifications
Wavelength Range200~960nm
Wavelength Accuracy± 2nm
Wavelength Repeatability< 0.5nm
Photometric Range0.0~199.9%T
-0.3~2.999A
1~9999F
0~9999C
Spectral Slit Width2nm
Transmittance Accuracy± 0.5%T
Transmittance Repeatability< 0.3%T
Stray Light< 0.2%T(220nmNal)
For more information
https://angstromadvancedinc.wordpress.com/
http://angstrom-advanced1.blogspot.com/
http://angstrom-advanced.blogspot.com/
https://www.facebook.com/Angstrom-Advanced-121251874597862/
http://angstromadvancedinc1.blogspot.com
https://twitter.com/AngstromAdvance

Angstrom Advanced Liquid Nitrogen/Oxygen/Argon Generating Plant


Introduction
Angstrom-Advanced Liquid Nitrogen/Oxygen/Argon Plant by Cryogenic Technology are top of the line systems.Our Generator applications range
from 5-10000 liters of Liquid Nitrogen/Oxygen per hour and 1-500 Liquid Argon per hour.
Cryogenic Engine features Fully Automatic G-M cold head with integral controls. Includes high efficiency frequency drive with water cooling
or optional air cooling. Fully automatic PLC based controls provide many features and modes including auto start, timed run,auto purge, etc.
Optional Chiller can be attached to liquefier unit when ordered at time of fabrication to allow continious operation up to 45 C
Specifications
N2 capacity5-10,000 L/h
N2 purity %Greater than 99.9999%
O2 capacity5-10,000 L/h
O2 purity %Greater than 99.95%
Argon capacity1-500 L/h
Argon purity %Greater than 99.9999%
Input Air pressure0-2 MPa
Power SupplyAC 220V/50Hz, 110V/60Hz
Temperature-195 degrees C
Work pressure0-2 MPa

For more information
https://angstromadvancedinc.wordpress.com/
http://angstrom-advanced1.blogspot.com/
http://angstrom-advanced.blogspot.com/
https://www.facebook.com/Angstrom-Advanced-121251874597862/
http://angstromadvancedinc1.blogspot.com
https://twitter.com/AngstromAdvance

Angstrom Advanced Nitrogen Purifying System


Introduction
The purity of nitrogen generated by nitrogen generator can range from 95% to 99.99%. If higher purity is required, a non-hydrogen or
hydrogen-using purifying system can be equipped.This system is installed after the Nitrogen Generator and further removes oxygen
and other by-products.As a result, a final purity of 99.9995% or above is achieved. Angstrom Advanced Inc supplies the non-hydrogen
deoxidizing purifying system and hydrogen deoxidizing purifying system.
Specifications
N2 capacity1-3000 Nm3/h
N2 purity %>99.9995%
Dew Point-70C
Oxygen Content>5 ppm

For more information
https://angstromadvancedinc.wordpress.com/
http://angstrom-advanced1.blogspot.com/
http://angstrom-advanced.blogspot.com/
https://www.facebook.com/Angstrom-Advanced-121251874597862/
http://angstromadvancedinc1.blogspot.com
https://twitter.com/AngstromAdvance

Angstrom Advanced Nitrogen Generating Plant by Membrane Separation


Introduction
The compressed air compressor filter into the polymer membrane filters, a variety of gas in the film in the solubility and proliferation of
different factors, leading to different gases in the membrane penetration rate in a relatively different. According to the characteristics,
various gases can be divided into "rapid gas" and "slow gas". After being compacted and purified (to remove oil, water and dust) the air
will enter the membrane separation to separate. First, the O2, CO2 and some vapor will infiltrate into the membrane wall and then exit
through the discharge port by air pressure; since the infiltrating speed of N2 is slower, it will flow out from the gas collector at the end of
the pressure box and finally enter nitrogen buffer tank.
Specifications
N2 capacity1-1000 Nm3/h
N2 purity %>95-99.9%
Dew Point-40C
Work pressure0-2.0 MPa
Features
-Controlled and managed by computers, can run automatically without any supervision.
-Simple start-up and shut-down procedure; in less than 2 minutes the system reaches normal and stable gas supply.
-No moving parts and minimal maintenance is required.
-Lightweight, with compact structure and small coverage.
-Free adjustment of purity between 95% and 99.9% via flow
-Based on users on-site configuration, Nitrogen systems of different specifications are available; join-up with other nitrogen purifying devices
is also possible.